Bitumen AH Grade – Aryl Hydrocarbon Bitumen

August 10, 2019
3 minutes

Infinity Galaxy supplies Aryl Hydrocarbon Bitumen or AH Grades. AH grades are as below:

AH grades are mostly used in China.

AH-50 Specifications


Specification of Infinity Galaxy Bitumen AH-50
SPECIFICATIONUNITVALUE TEST METHOD
Penetration1/10 Millimetres (mm40-50ASTM D5
Softening PointDegree Celsius (°C)48-56ASTM D36
Density, 25°CKilogram per Cubic Meter (kg/m³)1.000/1.060ASTM D71/D3289
Ductility, 25°CCentimetres per Second (cm/s)100 minASTM D113
Loss On HeatingWeight Percentage (WT%)0.2 MaxASTM D6
Drop-in Penetration After HeatingPercentage (%)20 maxASTM D6/D5
Flash Point (Cleveland Open Cup)Degree Celsius (°C)250 minASTM D92
Solubility in TrichloroethyleneWeight Percentage (WT%)99.5 minASTM D4
Spot TestNegative (−) or Positive (+)NegativeAASHOT 102 *
Bitumen ContentPercentage 99.9 minASTM D4


AH-70 Specifications


Specification of Infinity Galaxy Bitumen AH-70
SPECIFICATIONUNITVALUE TEST METHOD
Penetration, 25 °C1/10 Millimeters (mm)70-80ASTM D5
Softening PointDegree Celsius (°C)Min 42ASTM D36
Density, 215 °CGram per Cubic Meter (g/m³)1.000/1.060ASTM D70
Ductility, 15 °C, 5CM/MINCentimetersMin 100ASTM D113
Flash Point Degree Celsius (°C)Min 260ASTM D92
Dynamic Viscosity 60 °CPA.SMin 130ASTM D2171
Ductility, 10 °C, 5CM/MINCentimetersMin 20ASTM D113
Solubility in TrichloroethyleneWeight Percentage (WT%)Min 99.5ASTM D 2042
Wax ContentWeight Percentage (WT%)EN 12606-1
Penetration Index-1.5/1.0
AFTER TFOT AT 163 ˚C ASTM D1754
Loss on HeatingWeight Percentage (WT%)-0.8/0.8ASTMD1754
Retained PenetrationPercentage(%)Min 61ASTM D5
Ductility, 25°C, 5CM/MINCentimetersMin 6ASTM D113


AH-90 Specification


Specification of Infinity Galaxy Bitumen AH-90
SPECIFICATIONUNITVALUE TEST METHOD
Penetration1/10 Millimetres (mm80-100ASTM D5
Softening PointDegree Celsius (°C)42-52ASTM D36
Density, 25°CKilogram per Cubic Meter (kg/m³)1.000/1.060ASTM D71/D3289
Ductility, 25°CCentimetres per Second (cm/s)100 minASTM D113
Loss On HeatingWeight Percentage (WT%)0.5 MaxASTM D6
Drop-in Penetration After HeatingPercentage (%)20 maxASTM D6/D5
Flash Point (Cleveland Open Cup)Degree Celsius (°C)225 minASTM D92
Solubility in TrichloroethyleneWeight Percentage (WT%)99 minASTM D4
Loss of WeightPercentage (%)0.8 maxASTM D1754
Retained Penetration After Thin FilmPercentage (%)50 minASTM D5
Ductility 25°C After Thin Film OvenCentimetres per Second (cm/s)100 minASTM D113
Ductility 15°C After Thin Film OvenCentimetres per Second (cm/s)100 minASTM D113
TemperatureDegree Celsius (°C)Max 90-110 above the Soft
Bitumen ContentPercentage (%)99.9 minASTM D4


AH-110 Specifications


Specification of Infinity Galaxy Bitumen AH-110
SPECIFICATIONUNITVALUE TEST METHOD
Penetration1/10 Millimetres (mm80-110ASTM D5
Softening PointDegree Celsius (°C)45-52ASTM D36
Density, 25°CKilogram per Cubic Meter (kg/m³)1.000/1.060ASTM D71/D3289
Ductility, 25°CCentimetres per Second (cm/s)100 minASTM D113
Loss On HeatingWeight Percentage (WT%)0.5 MaxASTM D6
Drop-in Penetration After HeatingPercentage (%)20 maxASTM D6/D5
Flash Point (Cleveland Open Cup)Degree Celsius (°C)225 minASTM D92
Solubility in TrichloroethyleneWeight Percentage (WT%)99 minASTM D4
Loss of WeightPercentage (%)0.8 maxASTM D1754
Retained Penetration After Thin FilmPercentage (%)50 minASTM D5
Ductility 25°C After Thin Film OvenCentimetres per Second (cm/s)100 minASTM D113
Ductility 15°C After Thin Film OvenCentimetres per Second (cm/s)100 minASTM D113
TemperatureDegree Celsius (°C)Max 90-110 above the Soft
Bitumen ContentPercentage (%)99.9 minASTM D4


AH-130 Specifications


Specification of Infinity Galaxy Bitumen AH-130
SPECIFICATIONUNITVALUE TEST METHOD
Penetration1/10 Millimetres (mm80-130ASTM D5
Softening PointDegree Celsius (°C)42-52ASTM D36
Density, 25°CKilogram per Cubic Meter (kg/m³)1.000/1.060ASTM D71/D3289
Ductility, 25°CCentimetres per Second (cm/s)100 minASTM D113
Loss On HeatingWeight Percentage (WT%)0.5 MaxASTM D6
Drop-in Penetration After HeatingPercentage (%)20 maxASTM D6/D5
Flash Point (Cleveland Open Cup)Degree Celsius (°C)225 minASTM D92
Solubility in TrichloroethyleneWeight Percentage (WT%)99 minASTM D4
Loss of WeightPercentage (%)0.8 maxASTM D1754
Retained Penetration After Thin FilmPercentage (%)50 minASTM D5
Ductility 25°C After Thin Film OvenCentimetres per Second (cm/s)100 minASTM D113
Ductility 15°C After Thin Film OvenCentimetres per Second (cm/s)100 minASTM D113
TemperatureDegree Celsius (°C)Max 90-110 above the Soft
Bitumen ContentPercentage (%)99.9 minASTM D4


Check out our article about bitumen tests that determine the quality of bitumen

Rate this article.

Average rating / 5. Vote count:

Related articles

  • AC Grade Bitumen

    Zahra Esmaili
  • Bitumen Emulsion Advantages and Disadvantages

    Different Types of Cutback Bitumen and Their Grades

    Mona Zahedi
  • Bitumen Emulsion Advantages and Disadvantages

    Bitumen Emulsion CSS-1h

    Mona Zahedi

Leave a comment

Your email address will not be published. Required fields are marked *

Ahmad Reza Yousefi

August 10, 2019
3 minutes
()